Ultrabroadband sources, such as multiplexed superluminescent diodes (SLDs) and femtosecond lasers, have been successfully employed in adaptive optics optical coherence tomography (AO-OCT) systems for ultrahigh resolution retinal imaging. The large cost differential of these sources, however, motivates the need for a performance comparison. Here, we compare the performance of a Femtolasers Integral Ti:Sapphire laser and a Superlum BroadLighter T840, using the same AO-OCT system and the same subject. In addition, we investigate the capability of our instrument equipped with the Integral to capture volume images of the fovea and adjacent regions on a second subject using the AO to control focus in the retina and custom and freeware image registration software to reduce eye motion artifacts. Monochromatic ocular aberrations were corrected with a woofer-tweeter AO system. Coherence lengths of the Integral and BroadLighter were measured in vivo at 3.2 mu m and 3.3 mu m, respectively. The difference in dynamic range was 5 dB, close to the expected variability of the experiment. Individual cone photoreceptors, retinal capillaries and nerve fiber bundles were distinguished in all three dimensions with both sources. The acquired retinal volumes are provided for viewing in OSA ISP, allowing the reader to data mine at the microscope level. (C) 2009 Optical Society of America

Original languageEnglish
Pages (from-to)4095-4111
Number of pages17
JournalOptics Express
Volume17
Issue number5
DOIs
Publication statusPublished - 2 Mar 2009
Externally publishedYes

Cite this

Cense, Barry ; Koperda, Eric ; Brown, Jeffrey M. ; Kocaoglu, Omer P. ; Gao, Weihua ; Jonnal, Ravi S. ; Miller, Donald T. / Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources. In: Optics Express. 2009 ; Vol. 17, No. 5. pp. 4095-4111.
@article{2cb569841c2447dc8de28cc46730ae50,
title = "Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources",
abstract = "Ultrabroadband sources, such as multiplexed superluminescent diodes (SLDs) and femtosecond lasers, have been successfully employed in adaptive optics optical coherence tomography (AO-OCT) systems for ultrahigh resolution retinal imaging. The large cost differential of these sources, however, motivates the need for a performance comparison. Here, we compare the performance of a Femtolasers Integral Ti:Sapphire laser and a Superlum BroadLighter T840, using the same AO-OCT system and the same subject. In addition, we investigate the capability of our instrument equipped with the Integral to capture volume images of the fovea and adjacent regions on a second subject using the AO to control focus in the retina and custom and freeware image registration software to reduce eye motion artifacts. Monochromatic ocular aberrations were corrected with a woofer-tweeter AO system. Coherence lengths of the Integral and BroadLighter were measured in vivo at 3.2 mu m and 3.3 mu m, respectively. The difference in dynamic range was 5 dB, close to the expected variability of the experiment. Individual cone photoreceptors, retinal capillaries and nerve fiber bundles were distinguished in all three dimensions with both sources. The acquired retinal volumes are provided for viewing in OSA ISP, allowing the reader to data mine at the microscope level. (C) 2009 Optical Society of America",
keywords = "HIGH-SPEED",
author = "Barry Cense and Eric Koperda and Brown, {Jeffrey M.} and Kocaoglu, {Omer P.} and Weihua Gao and Jonnal, {Ravi S.} and Miller, {Donald T.}",
year = "2009",
month = "3",
day = "2",
doi = "10.1364/OE.17.004095",
language = "English",
volume = "17",
pages = "4095--4111",
journal = "Optics Express",
issn = "1094-4087",
publisher = "Optical Soc Amer",
number = "5",

}

Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources. / Cense, Barry; Koperda, Eric; Brown, Jeffrey M.; Kocaoglu, Omer P.; Gao, Weihua; Jonnal, Ravi S.; Miller, Donald T.

In: Optics Express, Vol. 17, No. 5, 02.03.2009, p. 4095-4111.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources

AU - Cense, Barry

AU - Koperda, Eric

AU - Brown, Jeffrey M.

AU - Kocaoglu, Omer P.

AU - Gao, Weihua

AU - Jonnal, Ravi S.

AU - Miller, Donald T.

PY - 2009/3/2

Y1 - 2009/3/2

N2 - Ultrabroadband sources, such as multiplexed superluminescent diodes (SLDs) and femtosecond lasers, have been successfully employed in adaptive optics optical coherence tomography (AO-OCT) systems for ultrahigh resolution retinal imaging. The large cost differential of these sources, however, motivates the need for a performance comparison. Here, we compare the performance of a Femtolasers Integral Ti:Sapphire laser and a Superlum BroadLighter T840, using the same AO-OCT system and the same subject. In addition, we investigate the capability of our instrument equipped with the Integral to capture volume images of the fovea and adjacent regions on a second subject using the AO to control focus in the retina and custom and freeware image registration software to reduce eye motion artifacts. Monochromatic ocular aberrations were corrected with a woofer-tweeter AO system. Coherence lengths of the Integral and BroadLighter were measured in vivo at 3.2 mu m and 3.3 mu m, respectively. The difference in dynamic range was 5 dB, close to the expected variability of the experiment. Individual cone photoreceptors, retinal capillaries and nerve fiber bundles were distinguished in all three dimensions with both sources. The acquired retinal volumes are provided for viewing in OSA ISP, allowing the reader to data mine at the microscope level. (C) 2009 Optical Society of America

AB - Ultrabroadband sources, such as multiplexed superluminescent diodes (SLDs) and femtosecond lasers, have been successfully employed in adaptive optics optical coherence tomography (AO-OCT) systems for ultrahigh resolution retinal imaging. The large cost differential of these sources, however, motivates the need for a performance comparison. Here, we compare the performance of a Femtolasers Integral Ti:Sapphire laser and a Superlum BroadLighter T840, using the same AO-OCT system and the same subject. In addition, we investigate the capability of our instrument equipped with the Integral to capture volume images of the fovea and adjacent regions on a second subject using the AO to control focus in the retina and custom and freeware image registration software to reduce eye motion artifacts. Monochromatic ocular aberrations were corrected with a woofer-tweeter AO system. Coherence lengths of the Integral and BroadLighter were measured in vivo at 3.2 mu m and 3.3 mu m, respectively. The difference in dynamic range was 5 dB, close to the expected variability of the experiment. Individual cone photoreceptors, retinal capillaries and nerve fiber bundles were distinguished in all three dimensions with both sources. The acquired retinal volumes are provided for viewing in OSA ISP, allowing the reader to data mine at the microscope level. (C) 2009 Optical Society of America

KW - HIGH-SPEED

U2 - 10.1364/OE.17.004095

DO - 10.1364/OE.17.004095

M3 - Article

VL - 17

SP - 4095

EP - 4111

JO - Optics Express

JF - Optics Express

SN - 1094-4087

IS - 5

ER -