TY - JOUR
T1 - Using microperimetry and low-luminance visual acuity to detect the onset of late age-related macular degeneration
T2 - A LEAD Study Report
AU - LEAD Study Group
AU - Wu, Zhichao
AU - Luu, Chi D.
AU - Hodgson, Lauren A.B.
AU - Caruso, Emily
AU - Chen, Fred K.
AU - Chakravarthy, Usha
AU - Arnold, Jennifer J.
AU - Heriot, Wilson J.
AU - Runciman, Jim
AU - Guymer, Robyn H.
PY - 2021/5/1
Y1 - 2021/5/1
N2 - PURPOSE: To evaluate the performance of microperimetry and low-luminance visual acuity for detecting late age-related macular degeneration (AMD) onset. METHODS: Two hundred ninety-two individuals with bilateral large drusen in the Laser Intervention in the Early Stages of AMD study underwent best-corrected visual acuity, low-luminance visual acuity, and microperimetry testing as well as multimodal imaging to detect late (neovascular or atrophic) AMD onset. The performance of the change in the measurement from baseline of each of visual function test for detecting late AMD onset was compared. RESULTS: The area under the receiver operating characteristic curve for detecting neovascular and atrophic AMD onset was not significantly different for low-luminance visual acuity (area under the receiver operating characteristic curve = 0.71 and 0.56, respectively) and microperimetry (area under the receiver operating characteristic curve = 0.82 and 0.62, respectively) compared with best-corrected visual acuity (area under the receiver operating characteristic curve = 0.57 and 0.56, respectively; P ≥ 0.126 for all). There was also only a fair degree of agreement between the three visual function measures for detecting the onset of neovascular and atrophic AMD (κ ≥ 0.24). CONCLUSION: Microperimetry, low-luminance visual acuity, and best-corrected visual acuity demonstrate limited performance for detecting the earliest onset of late AMD. It remains to be established whether they perform better than current methods designed to enable self-detection of neovascular AMD onset, such as Amsler grid testing.
AB - PURPOSE: To evaluate the performance of microperimetry and low-luminance visual acuity for detecting late age-related macular degeneration (AMD) onset. METHODS: Two hundred ninety-two individuals with bilateral large drusen in the Laser Intervention in the Early Stages of AMD study underwent best-corrected visual acuity, low-luminance visual acuity, and microperimetry testing as well as multimodal imaging to detect late (neovascular or atrophic) AMD onset. The performance of the change in the measurement from baseline of each of visual function test for detecting late AMD onset was compared. RESULTS: The area under the receiver operating characteristic curve for detecting neovascular and atrophic AMD onset was not significantly different for low-luminance visual acuity (area under the receiver operating characteristic curve = 0.71 and 0.56, respectively) and microperimetry (area under the receiver operating characteristic curve = 0.82 and 0.62, respectively) compared with best-corrected visual acuity (area under the receiver operating characteristic curve = 0.57 and 0.56, respectively; P ≥ 0.126 for all). There was also only a fair degree of agreement between the three visual function measures for detecting the onset of neovascular and atrophic AMD (κ ≥ 0.24). CONCLUSION: Microperimetry, low-luminance visual acuity, and best-corrected visual acuity demonstrate limited performance for detecting the earliest onset of late AMD. It remains to be established whether they perform better than current methods designed to enable self-detection of neovascular AMD onset, such as Amsler grid testing.
UR - http://www.scopus.com/inward/record.url?scp=85105761131&partnerID=8YFLogxK
U2 - 10.1097/IAE.0000000000002982
DO - 10.1097/IAE.0000000000002982
M3 - Article
C2 - 33009222
AN - SCOPUS:85105761131
SN - 0275-004X
VL - 41
SP - 1094
EP - 1101
JO - Retina (Philadelphia, Pa.)
JF - Retina (Philadelphia, Pa.)
IS - 5