TY - JOUR
T1 - Using Clinically Accessible Tools to Measure Sound Levels and Sleep Disruption in the ICU
T2 - A Prospective Multicenter Observational Study
AU - Litton, Edward
AU - Elliott, Rosalind
AU - Thompson, Kelly
AU - Watts, Nicola
AU - Seppelt, Ian
AU - Webb, Steven A.R.
AU - on behalf of The ANZICS Clinical Trials Group and The George Institute for Global Health
PY - 2017
Y1 - 2017
N2 - OBJECTIVES:: To use clinically accessible tools to determine unit-level and individual patient factors associated with sound levels and sleep disruption in a range of representative ICUs. DESIGN:: A cross-sectional, observational study. SETTING:: Australian and New Zealand ICUs. PATIENTS:: All patients 16 years or over occupying an ICU bed on one of two Point Prevalence study days in 2015. INTERVENTIONS:: Ambient sound was measured for 1 minute using an application downloaded to a personal mobile device. Bedside nurses also recorded the total time and number of awakening for each patient overnight. MEASUREMENTS AND MAIN RESULTS:: The study included 539 participants with sound level recorded using an application downloaded to a personal mobile device from 39 ICUs. Maximum and mean sound levels were 78 dB (SD, 9) and 62 dB (SD, 8), respectively. Maximum sound levels were higher in ICUs with a sleep policy or protocol compared with those without maximum sound levels 81 dB (95% CI, 79–83) versus 77 dB (95% CI, 77–78), mean difference 4 dB (95% CI, 0–2), p < 0.001. There was no significant difference in sound levels regardless of single room occupancy, mechanical ventilation status, or illness severity. Clinical nursing staff in all 39 ICUs were able to record sleep assessment in 15-minute intervals. The median time awake and number of prolonged disruptions were 3 hours (interquartile range, 1–4) and three (interquartile range, 2–5), respectively. CONCLUSIONS:: Across a large number of ICUs, patients were exposed to high sound levels and substantial sleep disruption irrespective of factors including previous implementation of a sleep policy. Sound and sleep measurement using simple and accessible tools can facilitate future studies and could feasibly be implemented into clinical practice.
AB - OBJECTIVES:: To use clinically accessible tools to determine unit-level and individual patient factors associated with sound levels and sleep disruption in a range of representative ICUs. DESIGN:: A cross-sectional, observational study. SETTING:: Australian and New Zealand ICUs. PATIENTS:: All patients 16 years or over occupying an ICU bed on one of two Point Prevalence study days in 2015. INTERVENTIONS:: Ambient sound was measured for 1 minute using an application downloaded to a personal mobile device. Bedside nurses also recorded the total time and number of awakening for each patient overnight. MEASUREMENTS AND MAIN RESULTS:: The study included 539 participants with sound level recorded using an application downloaded to a personal mobile device from 39 ICUs. Maximum and mean sound levels were 78 dB (SD, 9) and 62 dB (SD, 8), respectively. Maximum sound levels were higher in ICUs with a sleep policy or protocol compared with those without maximum sound levels 81 dB (95% CI, 79–83) versus 77 dB (95% CI, 77–78), mean difference 4 dB (95% CI, 0–2), p < 0.001. There was no significant difference in sound levels regardless of single room occupancy, mechanical ventilation status, or illness severity. Clinical nursing staff in all 39 ICUs were able to record sleep assessment in 15-minute intervals. The median time awake and number of prolonged disruptions were 3 hours (interquartile range, 1–4) and three (interquartile range, 2–5), respectively. CONCLUSIONS:: Across a large number of ICUs, patients were exposed to high sound levels and substantial sleep disruption irrespective of factors including previous implementation of a sleep policy. Sound and sleep measurement using simple and accessible tools can facilitate future studies and could feasibly be implemented into clinical practice.
UR - http://www.scopus.com/inward/record.url?scp=85016620987&partnerID=8YFLogxK
U2 - 10.1097/CCM.0000000000002405
DO - 10.1097/CCM.0000000000002405
M3 - Article
C2 - 28362644
AN - SCOPUS:85016620987
SN - 0090-3493
VL - 45
SP - 966
EP - 971
JO - Critical Care Medicine
JF - Critical Care Medicine
IS - 6
ER -