T1 - The introduction of umbilical cord lactate measurement and associated neonatal outcomes in a South African tertiary hospital labor ward
AU - Allanson, E. R.
AU - Pattinson, R.C.
AU - Nathan, E. A.
AU - Dickinson, J. E.
PY - 2018/5/19
Y1 - 2018/5/19
N2 - Purpose: To investigate the utility of umbilical artery (UA) lactate measurements in a South African hospital for assessing intrapartum care and predicting neonatal outcomes. Materials and methods: From 3 March–12 November 2014, we conducted a prospective cohort study of UA lactate levels at Kalafong Hospital, Pretoria, South Africa. Following birth, a UA blood sample (<0.5uL) was taken from a double-clamped segment of cord and the lactate measured. Maternal and neonatal characteristics and outcomes were recorded. Results: During the study, there were 4668 deliveries; including 1091 emergency cesarean and 154 instrumental deliveries. A lactate was recorded for 946 deliveries (20.3%). 190 babies required neonatal resuscitation, with an optimal cutoff for lactate of 5.45 mmol/L (sensitivity 68%, specificity 72%). 124 babies required nursery admission with the optimal cutoff for lactate 4.95 mmol/L (sensitivity 61%, specificity 59%). 55 babies had an Apgar score <7 at 5 min and the optimal lactate for this outcome was 5.65 mmol/L (sensitivity 64%, specificity of 69%). Conclusions: Umbilical lactate can be used in a middle-low resource setting as a measurement of intrapartum hypoxia, with reasonable sensitivity and specificity for the prediction of, or need for, resuscitation, admission to the nursery, and low Apgar scores.
AB - Purpose: To investigate the utility of umbilical artery (UA) lactate measurements in a South African hospital for assessing intrapartum care and predicting neonatal outcomes. Materials and methods: From 3 March–12 November 2014, we conducted a prospective cohort study of UA lactate levels at Kalafong Hospital, Pretoria, South Africa. Following birth, a UA blood sample (<0.5uL) was taken from a double-clamped segment of cord and the lactate measured. Maternal and neonatal characteristics and outcomes were recorded. Results: During the study, there were 4668 deliveries; including 1091 emergency cesarean and 154 instrumental deliveries. A lactate was recorded for 946 deliveries (20.3%). 190 babies required neonatal resuscitation, with an optimal cutoff for lactate of 5.45 mmol/L (sensitivity 68%, specificity 72%). 124 babies required nursery admission with the optimal cutoff for lactate 4.95 mmol/L (sensitivity 61%, specificity 59%). 55 babies had an Apgar score <7 at 5 min and the optimal lactate for this outcome was 5.65 mmol/L (sensitivity 64%, specificity of 69%). Conclusions: Umbilical lactate can be used in a middle-low resource setting as a measurement of intrapartum hypoxia, with reasonable sensitivity and specificity for the prediction of, or need for, resuscitation, admission to the nursery, and low Apgar scores.
KW - intrapartum
KW - Lactate
KW - neonatal
KW - resuscitation
KW - South Africa
UR - http://www.scopus.com/inward/record.url?scp=85018462997&partnerID=8YFLogxK
U2 - 10.1080/14767058.2017.1315094
DO - 10.1080/14767058.2017.1315094
M3 - Article
C2 - 28372476
SN - 1476-7058
VL - 31
SP - 1272
EP - 1278
JO - Journal of Maternal-Fetal and Neonatal Medicine
JF - Journal of Maternal-Fetal and Neonatal Medicine
IS - 10
ER -