The Effect of Prestress on Vibration Behavior of Structures in Impedance Method Damage Detection

Xianhua Liu, Roshun Paurobally, Jie Pan

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Structural health monitoring or damage detection has long been a research interest for its great potential for life safety and economic benefits to the industrialized world. Structural vibration behavior is an essential signature of the integrity of structures and hence has been used for damage detection. Structural vibration impedance by way of piezoceramic patch excitation offers a local damage detection technique. It has been known that temperature change has adverse effects on the measured impedance result and can complicate the damage analysis. It is believed that one way of temperature influence on vibration is through adding thermal prestress to the structure. Prestress affects vibration in different ways on different structures and application problems. For the impedance method, prestress comes not only from temperature change but also from other sources such as wind, gravity and working load. This paper deals with prestress effects in the context of local vibration behavior of structures. A theoretical analysis is given on how prestress affects the vibration. Experimental impedance measurement results for piezoceramic patch excited vibration of simple structures such as plates under prestress are presented.
Original languageEnglish
Pages (from-to)401-406
JournalAdvanced Materials Research
Volume41-42
Publication statusPublished - 2008

Fingerprint

Damage detection
Structural health monitoring
Temperature
Gravitation
Economics

Cite this

@article{d3f1e7158e48423cb4b4a538dd231878,
title = "The Effect of Prestress on Vibration Behavior of Structures in Impedance Method Damage Detection",
abstract = "Structural health monitoring or damage detection has long been a research interest for its great potential for life safety and economic benefits to the industrialized world. Structural vibration behavior is an essential signature of the integrity of structures and hence has been used for damage detection. Structural vibration impedance by way of piezoceramic patch excitation offers a local damage detection technique. It has been known that temperature change has adverse effects on the measured impedance result and can complicate the damage analysis. It is believed that one way of temperature influence on vibration is through adding thermal prestress to the structure. Prestress affects vibration in different ways on different structures and application problems. For the impedance method, prestress comes not only from temperature change but also from other sources such as wind, gravity and working load. This paper deals with prestress effects in the context of local vibration behavior of structures. A theoretical analysis is given on how prestress affects the vibration. Experimental impedance measurement results for piezoceramic patch excited vibration of simple structures such as plates under prestress are presented.",
author = "Xianhua Liu and Roshun Paurobally and Jie Pan",
year = "2008",
language = "English",
volume = "41-42",
pages = "401--406",
journal = "Advanced Materials Research",
issn = "1022-6680",
publisher = "Trans Tech Publications",

}

The Effect of Prestress on Vibration Behavior of Structures in Impedance Method Damage Detection. / Liu, Xianhua; Paurobally, Roshun; Pan, Jie.

In: Advanced Materials Research, Vol. 41-42, 2008, p. 401-406.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The Effect of Prestress on Vibration Behavior of Structures in Impedance Method Damage Detection

AU - Liu, Xianhua

AU - Paurobally, Roshun

AU - Pan, Jie

PY - 2008

Y1 - 2008

N2 - Structural health monitoring or damage detection has long been a research interest for its great potential for life safety and economic benefits to the industrialized world. Structural vibration behavior is an essential signature of the integrity of structures and hence has been used for damage detection. Structural vibration impedance by way of piezoceramic patch excitation offers a local damage detection technique. It has been known that temperature change has adverse effects on the measured impedance result and can complicate the damage analysis. It is believed that one way of temperature influence on vibration is through adding thermal prestress to the structure. Prestress affects vibration in different ways on different structures and application problems. For the impedance method, prestress comes not only from temperature change but also from other sources such as wind, gravity and working load. This paper deals with prestress effects in the context of local vibration behavior of structures. A theoretical analysis is given on how prestress affects the vibration. Experimental impedance measurement results for piezoceramic patch excited vibration of simple structures such as plates under prestress are presented.

AB - Structural health monitoring or damage detection has long been a research interest for its great potential for life safety and economic benefits to the industrialized world. Structural vibration behavior is an essential signature of the integrity of structures and hence has been used for damage detection. Structural vibration impedance by way of piezoceramic patch excitation offers a local damage detection technique. It has been known that temperature change has adverse effects on the measured impedance result and can complicate the damage analysis. It is believed that one way of temperature influence on vibration is through adding thermal prestress to the structure. Prestress affects vibration in different ways on different structures and application problems. For the impedance method, prestress comes not only from temperature change but also from other sources such as wind, gravity and working load. This paper deals with prestress effects in the context of local vibration behavior of structures. A theoretical analysis is given on how prestress affects the vibration. Experimental impedance measurement results for piezoceramic patch excited vibration of simple structures such as plates under prestress are presented.

M3 - Article

VL - 41-42

SP - 401

EP - 406

JO - Advanced Materials Research

JF - Advanced Materials Research

SN - 1022-6680