@article{0e9015f928404467a1b3e41eb6333737,
title = "Targeted alveo-pleural fistula endobronchial valve treatment using ventilation scintigraphy",
abstract = "Persistent air-leaks can be difficult to localize in radiology. Bronchoscopic management of air-leaks requires identification of the leak's location to allow suitable targeted treatment. One-way endobronchial valves have become a suitable option for persistent air-leaks. In this report, a combination scintigraphy and one-way endobronchial valve treatment successfully resolved a persistent air-leak.",
keywords = "alveo-pleural fistula, bronchoscopy, endobronchial, interventional, valve",
author = "Calvin Sidhu and Shoba Ratnagobal and Rajesh Thomas and Lee, {Gary Y.C.} and Enya Drudy and Francis, {Roslyn J.}",
note = "Funding Information: Dr Niranjan Setty, Nurse Sue Morey, Nurse Siobhan Dormer, Nurse Chloe Charlesworth. Dr Peter Swift & Sir Charles Gairdner Hospital Nuclear Medicine Department. Publisher Copyright: {\textcopyright} 2023 The Authors. Respirology Case Reports published by John Wiley & Sons Australia, Ltd on behalf of The Asian Pacific Society of Respirology.",
year = "2023",
month = may,
doi = "10.1002/rcr2.1146",
language = "English",
volume = "11",
journal = "Respirology Case Reports",
issn = "2051-3380",
publisher = "John Wiley & Sons",
number = "5",
}