TY - JOUR
T1 - Retesting visual fields
T2 - utilizing prior information to decrease test-retest variability in glaucoma
AU - Turpin, Andrew
AU - Jankovic, Darko
AU - McKendrick, Allison M
PY - 2007/4
Y1 - 2007/4
N2 - PURPOSE: To determine whether sensitivity estimates from an individual's previous visual field tests can be incorporated into perimetric procedures to improve accuracy and reduce test-retest variability at subsequent visits.METHODS: Computer simulation was used to determine the error, distribution of errors and presentation count for a series of perimetric algorithms. Baseline procedures were Full Threshold and Zippy Estimation by Sequential Testing (ZEST). Retest strategies were (1) allowing ZEST to continue from the previous test without reinitializing the probability density function [pdf]; (2) running ZEST with a Gaussian pdf centered about the previous result; (3) retest minimizing uncertainty (REMU), a new procedure combining suprathreshold and ZEST procedures incorporating prior test information. Empiric visual field data of 265 control and 163 patients with glaucoma were input into the simulation. Four error conditions were modeled: patients who make no errors, 15% false-positive (FP) with 3% false-negative (FN) errors, 15% FN with 3% FP errors, and 20% FP with 20% FN errors.RESULTS: If sensitivity was stable from test to retest, all the retest algorithms were faster than the baseline algorithms by, on average, one presentation per location and are significantly more accurate (P < 0.05). When visual fields changed from test to retest, REMU was faster and more accurate than the other retest approaches and the baseline procedures. Relative to the baseline procedures, REMU showed decreased test-retest variability in impaired regions of visual field.CONCLUSIONS: The obvious approaches to retest, such as continuing the previous procedure or seeding with previous values, have limitations when sensitivity changes between tests. REMU, however, significantly improves both accuracy and precision of testing and displays minimal bias, even when fields change and patients make errors.
AB - PURPOSE: To determine whether sensitivity estimates from an individual's previous visual field tests can be incorporated into perimetric procedures to improve accuracy and reduce test-retest variability at subsequent visits.METHODS: Computer simulation was used to determine the error, distribution of errors and presentation count for a series of perimetric algorithms. Baseline procedures were Full Threshold and Zippy Estimation by Sequential Testing (ZEST). Retest strategies were (1) allowing ZEST to continue from the previous test without reinitializing the probability density function [pdf]; (2) running ZEST with a Gaussian pdf centered about the previous result; (3) retest minimizing uncertainty (REMU), a new procedure combining suprathreshold and ZEST procedures incorporating prior test information. Empiric visual field data of 265 control and 163 patients with glaucoma were input into the simulation. Four error conditions were modeled: patients who make no errors, 15% false-positive (FP) with 3% false-negative (FN) errors, 15% FN with 3% FP errors, and 20% FP with 20% FN errors.RESULTS: If sensitivity was stable from test to retest, all the retest algorithms were faster than the baseline algorithms by, on average, one presentation per location and are significantly more accurate (P < 0.05). When visual fields changed from test to retest, REMU was faster and more accurate than the other retest approaches and the baseline procedures. Relative to the baseline procedures, REMU showed decreased test-retest variability in impaired regions of visual field.CONCLUSIONS: The obvious approaches to retest, such as continuing the previous procedure or seeding with previous values, have limitations when sensitivity changes between tests. REMU, however, significantly improves both accuracy and precision of testing and displays minimal bias, even when fields change and patients make errors.
KW - Algorithms
KW - Computer Simulation
KW - False Positive Reactions
KW - Glaucoma/diagnosis
KW - Humans
KW - Middle Aged
KW - Observer Variation
KW - Optic Nerve Diseases/diagnosis
KW - Predictive Value of Tests
KW - Scotoma/diagnosis
KW - Sensitivity and Specificity
KW - Sensory Thresholds
KW - Visual Field Tests/statistics & numerical data
KW - Visual Fields
U2 - 10.1167/iovs.06-1074
DO - 10.1167/iovs.06-1074
M3 - Article
C2 - 17389493
SN - 0146-0404
VL - 48
SP - 1627
EP - 1634
JO - Investigative ophthalmology & visual science
JF - Investigative ophthalmology & visual science
IS - 4
ER -