TY - JOUR
T1 - Prognostic Value of Ambulatory Blood Pressure in the Obese: The Ambulatory Blood Pressure-International Study
AU - Palatini, P.
AU - Reboldi, G.
AU - Beilin, Lawrence
AU - Casiglia, E.
AU - Eguchi, K.
AU - Imai, Y.
AU - Kario, K.
AU - Ohkubo, T.
AU - Pierdomenico, S.D.
AU - Schwartz, J.E.
AU - Wing, L.
AU - Verdecchia, P.
PY - 2016
Y1 - 2016
N2 - © 2016 Wiley Periodicals, Inc. The purpose of this study was to compare the predictive value of ambulatory blood pressure (BP) vs office BP for cardiovascular events during a 5.8-year follow-up period in the obese and nonobese participants of the Ambulatory Blood Pressure-International Study (n=10,817). Both ambulatory BP and office BP considered separately were predictive of cardiovascular events. However, in Cox models including both pressures, only ambulatory BP was associated with outcome. Among obese patients, the hazard ratios for a 10-mm Hg increase in 24-hour and office systolic BPs were 1.37 (95% confidence interval, 1.20-1.53) and 0.91 (95% confidence interval, 0.76-1.07), respectively. Among nonobese patients, the corresponding hazard ratios were 1.39 (95% confidence interval, 1.31-1.47) and 0.94 (95% confidence interval, 0.88-1.00) (P=not significant vs obese). Similar results were obtained for diastolic BP and for daytime and nighttime BPs. Ambulatory BP has similar predictive capacity in obese and nonobese patients, suggesting that ambulatory BP monitoring is a useful diagnostic tool for the assessment of obese individuals.
AB - © 2016 Wiley Periodicals, Inc. The purpose of this study was to compare the predictive value of ambulatory blood pressure (BP) vs office BP for cardiovascular events during a 5.8-year follow-up period in the obese and nonobese participants of the Ambulatory Blood Pressure-International Study (n=10,817). Both ambulatory BP and office BP considered separately were predictive of cardiovascular events. However, in Cox models including both pressures, only ambulatory BP was associated with outcome. Among obese patients, the hazard ratios for a 10-mm Hg increase in 24-hour and office systolic BPs were 1.37 (95% confidence interval, 1.20-1.53) and 0.91 (95% confidence interval, 0.76-1.07), respectively. Among nonobese patients, the corresponding hazard ratios were 1.39 (95% confidence interval, 1.31-1.47) and 0.94 (95% confidence interval, 0.88-1.00) (P=not significant vs obese). Similar results were obtained for diastolic BP and for daytime and nighttime BPs. Ambulatory BP has similar predictive capacity in obese and nonobese patients, suggesting that ambulatory BP monitoring is a useful diagnostic tool for the assessment of obese individuals.
UR - http://www.scopus.com/inward/record.url?scp=84958544246&partnerID=8YFLogxK
U2 - 10.1111/jch.12700
DO - 10.1111/jch.12700
M3 - Article
C2 - 26435165
VL - 18
SP - 111
EP - 118
JO - Journal of Clinical Hypertension
JF - Journal of Clinical Hypertension
SN - 1524-6175
IS - 2
ER -