TY - JOUR
T1 - Prestress Tension Measurement Using a Single Electromagnetic Sensor
AU - Guo, Xiao
AU - Deng, Nianchun
AU - Yu, Mengsheng
AU - Elchalakani, Mohamed
AU - Zhou, Yiming
PY - 2023/10
Y1 - 2023/10
N2 - Elasto-magnetic sensors are widely used to measure the tensile force of cable structures. Generally, the size of current elasto-magnetic sensors is designed to be large enough to measure the tensile force of the entire cable. Therefore, the tensile force of a single steel strand in cables cannot be measured, which causes some engineering problems, such as that the uniformity of prestress tension and forces within steel cables cannot be determined. In this study, a single-strand elasto-magnetic sensor, called the EM17 sensor, is proposed to detect and monitor the tensile force of single steel strands. EM17 is the smallest sensor developed to date, with an inner diameter of 17 mm. In addition, a series of experiments were conducted to investigate the effects of temperature, position, shielding environment, strand relaxation, strand fatigue and sensor sealing performance on sensor accuracy. The field tests show that the EM17 sensors can accurately measure the tensile force of steel strands. The results show that the uniformity of the prestressed steel strand and the error between measurement and target values are within the range of 5%, which is considered satisfactory.
AB - Elasto-magnetic sensors are widely used to measure the tensile force of cable structures. Generally, the size of current elasto-magnetic sensors is designed to be large enough to measure the tensile force of the entire cable. Therefore, the tensile force of a single steel strand in cables cannot be measured, which causes some engineering problems, such as that the uniformity of prestress tension and forces within steel cables cannot be determined. In this study, a single-strand elasto-magnetic sensor, called the EM17 sensor, is proposed to detect and monitor the tensile force of single steel strands. EM17 is the smallest sensor developed to date, with an inner diameter of 17 mm. In addition, a series of experiments were conducted to investigate the effects of temperature, position, shielding environment, strand relaxation, strand fatigue and sensor sealing performance on sensor accuracy. The field tests show that the EM17 sensors can accurately measure the tensile force of steel strands. The results show that the uniformity of the prestressed steel strand and the error between measurement and target values are within the range of 5%, which is considered satisfactory.
KW - Electromagnetic sensors
KW - Prestress tension monitoring
KW - Structural health monitoring
KW - Tension evaluation
KW - Uniformity detection
UR - http://www.scopus.com/inward/record.url?scp=85170091645&partnerID=8YFLogxK
U2 - 10.1007/s12205-023-0915-1
DO - 10.1007/s12205-023-0915-1
M3 - Article
AN - SCOPUS:85170091645
SN - 1226-7988
VL - 27
SP - 4323
EP - 4331
JO - KSCE Journal of Civil Engineering
JF - KSCE Journal of Civil Engineering
IS - 10
ER -