TY - JOUR
T1 - Pre-hydrated sterile acellular dermal matrix allograft in breast reconstruction
T2 - review of a single unit's experience
AU - James, Justin
AU - Corrigan, Brigid
AU - Saunders, Christobel
PY - 2018/4/1
Y1 - 2018/4/1
N2 - Background: The acellular dermal matrix (Flex HD) (FHD) became available for use in Western Australia in 2014 to aid prosthetic breast reconstruction and this descriptive study aims to review and discuss a single institution's experience since its introduction. Methods: By retrospective case note, review data were collected for all patients who underwent prosthetic breast reconstruction with the aid of FHD between January 2014 and August 2015 in our institution. Data on basic demographic parameters, risk factors, surgery-related factors, post-operative factors and follow-up information were collected. All complications were recorded and described in detail. Results: FHD was used in 42 breast reconstructions in 26 patients. Procedure-related complications were seen in 26% (n = 11) of cases. A major complication requiring return to theatre was seen in 11% (n = 5) of cases. Cellulitis of the reconstructed breast (red breast syndrome) was seen in 16.67% (n = 7) cases. Overall implant loss was 2.4% (n = 1). Of the six possible risk factors for any complication, only current smoking was found to increase the risk of complications (odds ratio = 9.667, 95% confidence interval = 1.429–65.377). Conclusion: FHD is associated with a relatively high overall complication rate. Use of this optional expensive material has to be carefully selected balancing its perceived advantages against this possible risk. The red breast syndrome merits further studies considering its frequent occurrence with FHD use.
AB - Background: The acellular dermal matrix (Flex HD) (FHD) became available for use in Western Australia in 2014 to aid prosthetic breast reconstruction and this descriptive study aims to review and discuss a single institution's experience since its introduction. Methods: By retrospective case note, review data were collected for all patients who underwent prosthetic breast reconstruction with the aid of FHD between January 2014 and August 2015 in our institution. Data on basic demographic parameters, risk factors, surgery-related factors, post-operative factors and follow-up information were collected. All complications were recorded and described in detail. Results: FHD was used in 42 breast reconstructions in 26 patients. Procedure-related complications were seen in 26% (n = 11) of cases. A major complication requiring return to theatre was seen in 11% (n = 5) of cases. Cellulitis of the reconstructed breast (red breast syndrome) was seen in 16.67% (n = 7) cases. Overall implant loss was 2.4% (n = 1). Of the six possible risk factors for any complication, only current smoking was found to increase the risk of complications (odds ratio = 9.667, 95% confidence interval = 1.429–65.377). Conclusion: FHD is associated with a relatively high overall complication rate. Use of this optional expensive material has to be carefully selected balancing its perceived advantages against this possible risk. The red breast syndrome merits further studies considering its frequent occurrence with FHD use.
KW - acellular dermal matrix
KW - breast reconstruction
KW - red breast syndrome
UR - http://www.scopus.com/inward/record.url?scp=85025464477&partnerID=8YFLogxK
U2 - 10.1111/ans.13857
DO - 10.1111/ans.13857
M3 - Article
C2 - 28727237
AN - SCOPUS:85025464477
SN - 1445-1433
VL - 88
SP - 369
EP - 373
JO - ANZ Journal of Surgery
JF - ANZ Journal of Surgery
IS - 4
ER -