T1 - Patient-specific prediction of SEEG electrode bending for stereotactic neurosurgical planning
AU - Granados, Alejandro
AU - Han, Yuxuan
AU - Lucena, Oeslle
AU - Vakharia, Vejay
AU - Rodionov, Roman
AU - Vos, Sjoerd B
AU - Miserocchi, Anna
AU - McEvoy, Andrew W
AU - Duncan, John S
AU - Sparks, Rachel
AU - Ourselin, Sébastien
PY - 2021/5
Y1 - 2021/5
N2 - PURPOSE : Electrode bending observed after stereotactic interventions is typically not accounted for in either computer-assisted planning algorithms, where straight trajectories are assumed, or in quality assessment, where only metrics related to entry and target points are reported. Our aim is to provide a fully automated and validated pipeline for the prediction of stereo-electroencephalography (SEEG) electrode bending. METHODS : We transform electrodes of 86 cases into a common space and compare features-based and image-based neural networks on their ability to regress local displacement ([Formula: see text]) or electrode bending ([Formula: see text]). Electrodes were stratified into six groups based on brain structures at the entry and target point. Models, both with and without Monte Carlo (MC) dropout, were trained and validated using tenfold cross-validation. RESULTS : mage-based models outperformed features-based models for all groups, and models that predicted [Formula: see text] performed better than for [Formula: see text]. Image-based model prediction with MC dropout resulted in lower mean squared error (MSE) with improvements up to 12.9% ([Formula: see text]) and 39.9% ([Formula: see text]), compared to no dropout. Using an image of brain tissue types (cortex, white and deep grey matter) resulted in similar, and sometimes better performance, compared to using a T1-weighted MRI when predicting [Formula: see text]. When inferring trajectories of image-based models (brain tissue types), 86.9% of trajectories had an MSE[Formula: see text] mm. CONCLUSION : An image-based approach regressing local displacement with an image of brain tissue types resulted in more accurate electrode bending predictions compared to other approaches, inputs, and outputs. Future work will investigate the integration of electrode bending into planning and quality assessment algorithms.
AB - PURPOSE : Electrode bending observed after stereotactic interventions is typically not accounted for in either computer-assisted planning algorithms, where straight trajectories are assumed, or in quality assessment, where only metrics related to entry and target points are reported. Our aim is to provide a fully automated and validated pipeline for the prediction of stereo-electroencephalography (SEEG) electrode bending. METHODS : We transform electrodes of 86 cases into a common space and compare features-based and image-based neural networks on their ability to regress local displacement ([Formula: see text]) or electrode bending ([Formula: see text]). Electrodes were stratified into six groups based on brain structures at the entry and target point. Models, both with and without Monte Carlo (MC) dropout, were trained and validated using tenfold cross-validation. RESULTS : mage-based models outperformed features-based models for all groups, and models that predicted [Formula: see text] performed better than for [Formula: see text]. Image-based model prediction with MC dropout resulted in lower mean squared error (MSE) with improvements up to 12.9% ([Formula: see text]) and 39.9% ([Formula: see text]), compared to no dropout. Using an image of brain tissue types (cortex, white and deep grey matter) resulted in similar, and sometimes better performance, compared to using a T1-weighted MRI when predicting [Formula: see text]. When inferring trajectories of image-based models (brain tissue types), 86.9% of trajectories had an MSE[Formula: see text] mm. CONCLUSION : An image-based approach regressing local displacement with an image of brain tissue types resulted in more accurate electrode bending predictions compared to other approaches, inputs, and outputs. Future work will investigate the integration of electrode bending into planning and quality assessment algorithms.
KW - Algorithms
KW - Brain/diagnostic imaging
KW - Electrodes, Implanted
KW - Electroencephalography/methods
KW - Humans
KW - Imaging, Three-Dimensional/methods
KW - Machine Learning
KW - Magnetic Resonance Imaging/methods
KW - Monte Carlo Method
KW - Neurosurgery/instrumentation
KW - Radiosurgery/methods
KW - Surgery, Computer-Assisted
U2 - 10.1007/s11548-021-02347-8
DO - 10.1007/s11548-021-02347-8
M3 - Article
C2 - 33761063
SN - 1861-6410
VL - 16
SP - 789
EP - 798
JO - International Journal of Computer Assisted Radiology and Surgery
JF - International Journal of Computer Assisted Radiology and Surgery
IS - 5
ER -