TY - JOUR
T1 - Of rats and rocks
T2 - 2021 International Symposium of the Society of Core Analysts
AU - Brattekås, Bergit
AU - Fernø, Martin A.
AU - Haugen, Malin
AU - Føyen, Tore
AU - Steinsbø, Marianne
AU - Graue, Arne
AU - Brekke, Njål
AU - Adamsen, Tom Christian Holm
AU - Rygh, Cecilie Brekke
AU - Espedal, Heidi
N1 - Publisher Copyright:
© The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/)
PY - 2023/1/27
Y1 - 2023/1/27
N2 - Positron emission tomography (PET) is routinely used for medical imaging; a current surge in published geoscientific research utilizing this modality also infer increasing interest for in-situ PET imaging in core analysis. Excellent signal to noise ratio coupled with high temporal and spatial resolution suggest that PET might become the new method-of-choice for core analysis. Obstacles related to production, transfer and handling of radioactive fluids and gases must, however, be dealt with for PET to become a widely used core scale imaging technique. This paper describes an ongoing, true multidisciplinary collaboration, where preclinical PET imaging facilities are routinely used in core analysis to investigate dynamic fluid flow at high pressure conditions. We detail challenges and opportunities related to porous media research in established pre-clinical laboratory facilities designed for small-animal imaging, and demonstrate the significant potential of PET imaging in core scale analysis in a context related to long-term porous media carbon storage. Explicit imaging of several fluid phases is possible by PET imaging using a range of readily available radiotracers. Relevant radiotracers to carbon storage in porous media are e.g. the carbon radioisotope 11C and water-soluble tracer 18F. These are both short-lived tracers (20-110 min) and must be used in high doses of radiation, which present challenges related to safe transfer and handling. Although there are several obstacles to conduct advanced core analysis in hospital imaging facilities (some of which are detailed in this paper), significant advantages include trained personnel on-site to operate a local cyclotron, procedures in place to ensure safe and efficient transfer of short-lived radiopharmaceuticals from the cyclotron, and advanced image analysis capabilities available. Cyclotrons are widely available worldwide (currently more than 1200 operating cyclotrons), often located in close proximity to medical and pre-clinical imaging facilities and academic institutions. Similar collaborations may therefore also be possible elsewhere, reducing the need for allocated geophysical PET-scanners and lowering the threshold for routinely using PET imaging in core analysis.
AB - Positron emission tomography (PET) is routinely used for medical imaging; a current surge in published geoscientific research utilizing this modality also infer increasing interest for in-situ PET imaging in core analysis. Excellent signal to noise ratio coupled with high temporal and spatial resolution suggest that PET might become the new method-of-choice for core analysis. Obstacles related to production, transfer and handling of radioactive fluids and gases must, however, be dealt with for PET to become a widely used core scale imaging technique. This paper describes an ongoing, true multidisciplinary collaboration, where preclinical PET imaging facilities are routinely used in core analysis to investigate dynamic fluid flow at high pressure conditions. We detail challenges and opportunities related to porous media research in established pre-clinical laboratory facilities designed for small-animal imaging, and demonstrate the significant potential of PET imaging in core scale analysis in a context related to long-term porous media carbon storage. Explicit imaging of several fluid phases is possible by PET imaging using a range of readily available radiotracers. Relevant radiotracers to carbon storage in porous media are e.g. the carbon radioisotope 11C and water-soluble tracer 18F. These are both short-lived tracers (20-110 min) and must be used in high doses of radiation, which present challenges related to safe transfer and handling. Although there are several obstacles to conduct advanced core analysis in hospital imaging facilities (some of which are detailed in this paper), significant advantages include trained personnel on-site to operate a local cyclotron, procedures in place to ensure safe and efficient transfer of short-lived radiopharmaceuticals from the cyclotron, and advanced image analysis capabilities available. Cyclotrons are widely available worldwide (currently more than 1200 operating cyclotrons), often located in close proximity to medical and pre-clinical imaging facilities and academic institutions. Similar collaborations may therefore also be possible elsewhere, reducing the need for allocated geophysical PET-scanners and lowering the threshold for routinely using PET imaging in core analysis.
UR - http://www.scopus.com/inward/record.url?scp=85147431849&partnerID=8YFLogxK
U2 - 10.1051/e3sconf/202336601011
DO - 10.1051/e3sconf/202336601011
M3 - Conference article
AN - SCOPUS:85147431849
VL - 366
JO - E3S Web of Conferences
JF - E3S Web of Conferences
IS - 01011
M1 - 01011
Y2 - 13 September 2021 through 16 September 2021
ER -