TY - JOUR
T1 - In vivo trueness of full-arch implant-supported CAD/CAM restorations and models based on conventional impressions
AU - Nedelcu, Robert
AU - Olsson, Pontus
AU - Thulin, Måns
AU - Nyström, Ingela
AU - Thor, Andreas
N1 - Funding Information:
This work has been supported by Nobel Biocare Services AG with research grant 2015-1372.
Publisher Copyright:
© 2022 The Authors
PY - 2023/1
Y1 - 2023/1
N2 - Objectives: To evaluate a method for in situ reference acquisition of implant positions in complete edentulous maxillae using an industrial scanner. To assess in vivo trueness of full-arch implant-supported fixed dentures (IFD) and dental models based on conventional impressions. Methods: In five subjects, scan-bodies were mounted to six maxillary implants and scanned three times using an industrial scanner (REF). Original impression-based models used to manufacture existing IFDs, (MOD1), and models fabricated from new polyether impressions, (MOD2), were scanned three times with a laboratory scanner. Scan-bodies were aligned and exported with analogue positions corresponding to implant positions. Implant analogues were mounted onto existing IFDs and scanned three times (BRIDGE). CAD files of scan-bodies with inter-aligned CAD-analogues were geometry-aligned to REF. CAD-analogues were aligned to exported files of MOD1 and MOD2, and to BRIDGE. Resulting six CAD-analogues were Globally Aligned using a consistent geometry-based alignment. Deviations were computed after a Reference Point System Alignment at the implant/prosthetic platform for Cartesian axes and a linear Resultant. Results: REF precision was 9.3 ± 1 µm. In vivo trueness for Resultant was MOD1: 36±16 µm, MOD2: 28±7 µm and BRIDGE: 70±23 µm, where MOD1 and MOD2 were statistically significantly different from BRIDGE. In vitro manufacturing trueness of Resultant when MOD1 acted reference for BRIDGE was: 69 ± 22. Conclusions: This method can be applied for assessing in vivo trueness. CAD/CAM processed IFD showed deviations twice that of impression-based models, however, errors from impressions and subsequent model scans were not additive to the entire workflow.
AB - Objectives: To evaluate a method for in situ reference acquisition of implant positions in complete edentulous maxillae using an industrial scanner. To assess in vivo trueness of full-arch implant-supported fixed dentures (IFD) and dental models based on conventional impressions. Methods: In five subjects, scan-bodies were mounted to six maxillary implants and scanned three times using an industrial scanner (REF). Original impression-based models used to manufacture existing IFDs, (MOD1), and models fabricated from new polyether impressions, (MOD2), were scanned three times with a laboratory scanner. Scan-bodies were aligned and exported with analogue positions corresponding to implant positions. Implant analogues were mounted onto existing IFDs and scanned three times (BRIDGE). CAD files of scan-bodies with inter-aligned CAD-analogues were geometry-aligned to REF. CAD-analogues were aligned to exported files of MOD1 and MOD2, and to BRIDGE. Resulting six CAD-analogues were Globally Aligned using a consistent geometry-based alignment. Deviations were computed after a Reference Point System Alignment at the implant/prosthetic platform for Cartesian axes and a linear Resultant. Results: REF precision was 9.3 ± 1 µm. In vivo trueness for Resultant was MOD1: 36±16 µm, MOD2: 28±7 µm and BRIDGE: 70±23 µm, where MOD1 and MOD2 were statistically significantly different from BRIDGE. In vitro manufacturing trueness of Resultant when MOD1 acted reference for BRIDGE was: 69 ± 22. Conclusions: This method can be applied for assessing in vivo trueness. CAD/CAM processed IFD showed deviations twice that of impression-based models, however, errors from impressions and subsequent model scans were not additive to the entire workflow.
KW - Accuracy
KW - Framework misfit
KW - Implant impression
KW - in vivo
KW - Precision
KW - Trueness
UR - http://www.scopus.com/inward/record.url?scp=85143492834&partnerID=8YFLogxK
U2 - 10.1016/j.jdent.2022.104381
DO - 10.1016/j.jdent.2022.104381
M3 - Article
C2 - 36574597
AN - SCOPUS:85143492834
SN - 0300-5712
VL - 128
JO - Journal of Dentistry
JF - Journal of Dentistry
M1 - 104381
ER -