Implementation of load sharing with fast voltage regulation in parallel connected cascaded power boost converters based on droop coefficients refreshing method

Davood Ghaderi, Mehmet Celebi

Research output: Chapter in Book/Conference paperConference paperpeer-review

3 Citations (Scopus)

Abstract

Droop control has been widely implemented in Parallel structures of DC DC converters due to its inherent modularity and ease of implementation. In this kind of converters with resistive distribution lines, the P-V droop with boost converters is the most common method for load sharing. Current or load sharing is the most critical parameter in parallel operation of converters. Most of the methods to guarantee equal load sharing utilize some form of communication between the units. This increases the complexity and sensitivity to noise. The method that has been considered in this paper is P-V control option. P-V droop controls the dc current depending on the dc voltage. In this technique, per 10 microseconds, droop coefficients will be refreshing by sampling by load current. This circuit is simulated by MATLAB/SIMULINK and CADENCE for preparing to instruction and the results of the simulation confirmed the theoretical design. This design has implemented on a parallel structure with two blocks of cascaded boost converters at laboratory scales.

Original languageEnglish
Title of host publicationProceedings - 9th International Conference on Computational Intelligence and Communication Networks, CICN 2017
EditorsBaki Koyuncu, Geetam S. Tomar
PublisherIEEE, Institute of Electrical and Electronics Engineers
Pages195-199
Number of pages5
ISBN (Electronic)9781509050017
DOIs
Publication statusPublished - 2 Jul 2017
Externally publishedYes
Event9th International Conference on Computational Intelligence and Communication Networks - Girne, Cyprus
Duration: 16 Sept 201717 Sept 2017

Publication series

NameProceedings - 9th International Conference on Computational Intelligence and Communication Networks, CICN 2017
Volume2018-January

Conference

Conference9th International Conference on Computational Intelligence and Communication Networks
Abbreviated titleCICN 2017
Country/TerritoryCyprus
CityGirne
Period16/09/1717/09/17

Fingerprint

Dive into the research topics of 'Implementation of load sharing with fast voltage regulation in parallel connected cascaded power boost converters based on droop coefficients refreshing method'. Together they form a unique fingerprint.

Cite this