T1 - Extraction of Thickness and Water-Content Gradients in Hydrogel-Based Water-Backed Corneal Phantoms Via Submillimeter-Wave Reflectometry
AU - Tamminen, Aleksi
AU - Baggio, Mariangela
AU - Nefedova, Irina
AU - Sun, Qiushuo
AU - Presnyakov, Semyon
AU - Ala-Laurinaho, Juha
AU - Brown, Elliott
AU - Wallace, Vincent
AU - Macpherson, Emma
AU - Maloney, Thaddeus
AU - Kravchenko, Natalya
AU - Salkola, Mika
AU - Deng, Sophie
AU - Taylor, Zachary
PY - 2021/11/1
Y1 - 2021/11/1
N2 - Absolute thickness and free-water-content gradients in gelatin-based corneal phantoms with physiologically accurate radii of curvature and aqueous backing were extracted via coherent submillimeter-wave reflectometry at 220-330 GHz. Fourier-domain-based calibration methods, utilizing temporal and spatial gating, were developed and yielded peak-to-peak amplitude and phase clutter of 10-3 and 0.1°, respectively, for signal-to-noise ratios (SNRs) between 40 and 50 dB. Total 12 phantoms were fabricated. Calibration methods enabled quantification of target sphericity that strongly correlated with optical-coherence tomography-based sphericity metrics via image segmentation. The extracted free-water volume fraction varied less than 5% in the five phantoms whose fabrication yielded the most spherical geometry. Submillimeter-wave-based thickness accuracy was better than 111 μm (∼λ/9) with an average of 65 μm (∼λ/17) and standard deviation of 44 μm (∼λ/25) for phantoms with physiologically relevant geometry. Monte-Carlo simulations of measurement noise and uncertainty limits agree with the experimental data analysis and indicate a lower thickness accuracy limit of 33 μm, and water-content sensitivities of 0.5% and 11.8% for the anterior and posterior segments, respectively. Numerical analysis suggests that the measurement fidelity was SNR limited and identified optical path length ambiguities within the cornea where a continuum of thickness/water gradient pairs produces statistically insignificant differences in complex reflection coefficient for finite SNR. This is the first known submillimeter-wave measurement technique, which is able to extract both the thickness and water-content gradients from a soft-tissue phantom, with a water backing, without the need for ancillary measurements.
AB - Absolute thickness and free-water-content gradients in gelatin-based corneal phantoms with physiologically accurate radii of curvature and aqueous backing were extracted via coherent submillimeter-wave reflectometry at 220-330 GHz. Fourier-domain-based calibration methods, utilizing temporal and spatial gating, were developed and yielded peak-to-peak amplitude and phase clutter of 10-3 and 0.1°, respectively, for signal-to-noise ratios (SNRs) between 40 and 50 dB. Total 12 phantoms were fabricated. Calibration methods enabled quantification of target sphericity that strongly correlated with optical-coherence tomography-based sphericity metrics via image segmentation. The extracted free-water volume fraction varied less than 5% in the five phantoms whose fabrication yielded the most spherical geometry. Submillimeter-wave-based thickness accuracy was better than 111 μm (∼λ/9) with an average of 65 μm (∼λ/17) and standard deviation of 44 μm (∼λ/25) for phantoms with physiologically relevant geometry. Monte-Carlo simulations of measurement noise and uncertainty limits agree with the experimental data analysis and indicate a lower thickness accuracy limit of 33 μm, and water-content sensitivities of 0.5% and 11.8% for the anterior and posterior segments, respectively. Numerical analysis suggests that the measurement fidelity was SNR limited and identified optical path length ambiguities within the cornea where a continuum of thickness/water gradient pairs produces statistically insignificant differences in complex reflection coefficient for finite SNR. This is the first known submillimeter-wave measurement technique, which is able to extract both the thickness and water-content gradients from a soft-tissue phantom, with a water backing, without the need for ancillary measurements.
KW - Corneal phantom
KW - gelatin hydrogel
KW - optical-coherence tomography
KW - submillimeter-wave spectroscopy
UR - http://www.scopus.com/inward/record.url?scp=85112620582&partnerID=8YFLogxK
U2 - 10.1109/TTHZ.2021.3099058
DO - 10.1109/TTHZ.2021.3099058
M3 - Article
AN - SCOPUS:85112620582
SN - 2156-342X
VL - 11
SP - 647
EP - 659
JO - IEEE Transactions on Terahertz Science and Technology
JF - IEEE Transactions on Terahertz Science and Technology
IS - 6