Combined loading of strip footings on sand-over-clay with layers of varying extents

Ali Haghighi, Pan Hu, Joe Tom Jr, Kristian Krabbenhoft

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This study describes the numerical analyses performed to investigate the bearing capacity of strip footings placed on granular (frictional) material overlying soft clay subjected to combined vertical-horizontal and vertical-moment loading. A plane-strain finite element limit analysis is used to estimate the limiting load combinations for two layer soil geometries where the top layer is either fully extended in the horizontal direction or it is of limited horizontal extent, representative of rock or gravel berms commonly used in offshore practice.

Bearing capacity envelopes for combined vertical, horizontal and/or moment loading are well-documented in the literature for cases of footings resting on single sand or clay soil. For two-layer sand-over-clay soil with a horizontally extensive top layer, the vertical-horizontal and vertical-moment envelopes initially coincide with the envelope for a single sand layer at low vertical loads, but show an abrupt reduction in the horizontal or moment capacity as the vertical load increases beyond a certain critical vertical load. The critical vertical load is found to vary as a function of the thickness and the lateral extent of the upper layer. Relationships are presented to enable the vertical-horizontal and vertical-moment envelopes to be estimated based on the problem geometry and material properties.

The findings in this study provide insight into the response of subsea foundations placed on rock or gravel of limited extent overlying a clay seabed as well as the general response of shallow foundations on two-layer profiles.
Original languageEnglish
Pages (from-to)433-442
Number of pages10
JournalSoils and Foundations
DOIs
Publication statusE-pub ahead of print - 5 Feb 2019

Fingerprint

footing
Clay
Sand
clay
sand
Gravel
Bearing capacity
Soils
Rocks
bearing capacity
clay soil
Geometry
gravel
geometry
limit analysis
Materials properties
plane strain
soft clay
rock

Cite this

@article{7b9965bc4c7949a18108e7e17519a629,
title = "Combined loading of strip footings on sand-over-clay with layers of varying extents",
abstract = "This study describes the numerical analyses performed to investigate the bearing capacity of strip footings placed on granular (frictional) material overlying soft clay subjected to combined vertical-horizontal and vertical-moment loading. A plane-strain finite element limit analysis is used to estimate the limiting load combinations for two layer soil geometries where the top layer is either fully extended in the horizontal direction or it is of limited horizontal extent, representative of rock or gravel berms commonly used in offshore practice.Bearing capacity envelopes for combined vertical, horizontal and/or moment loading are well-documented in the literature for cases of footings resting on single sand or clay soil. For two-layer sand-over-clay soil with a horizontally extensive top layer, the vertical-horizontal and vertical-moment envelopes initially coincide with the envelope for a single sand layer at low vertical loads, but show an abrupt reduction in the horizontal or moment capacity as the vertical load increases beyond a certain critical vertical load. The critical vertical load is found to vary as a function of the thickness and the lateral extent of the upper layer. Relationships are presented to enable the vertical-horizontal and vertical-moment envelopes to be estimated based on the problem geometry and material properties.The findings in this study provide insight into the response of subsea foundations placed on rock or gravel of limited extent overlying a clay seabed as well as the general response of shallow foundations on two-layer profiles.",
author = "Ali Haghighi and Pan Hu and {Tom Jr}, Joe and Kristian Krabbenhoft",
year = "2019",
month = "2",
day = "5",
doi = "10.1016/j.sandf.2018.12.004",
language = "English",
pages = "433--442",
journal = "Soils and Foundations",
issn = "0038-0806",
publisher = "Japanese Geotechnical Society",

}

Combined loading of strip footings on sand-over-clay with layers of varying extents. / Haghighi, Ali; Hu, Pan; Tom Jr, Joe; Krabbenhoft, Kristian.

In: Soils and Foundations, 05.02.2019, p. 433-442.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Combined loading of strip footings on sand-over-clay with layers of varying extents

AU - Haghighi, Ali

AU - Hu, Pan

AU - Tom Jr, Joe

AU - Krabbenhoft, Kristian

PY - 2019/2/5

Y1 - 2019/2/5

N2 - This study describes the numerical analyses performed to investigate the bearing capacity of strip footings placed on granular (frictional) material overlying soft clay subjected to combined vertical-horizontal and vertical-moment loading. A plane-strain finite element limit analysis is used to estimate the limiting load combinations for two layer soil geometries where the top layer is either fully extended in the horizontal direction or it is of limited horizontal extent, representative of rock or gravel berms commonly used in offshore practice.Bearing capacity envelopes for combined vertical, horizontal and/or moment loading are well-documented in the literature for cases of footings resting on single sand or clay soil. For two-layer sand-over-clay soil with a horizontally extensive top layer, the vertical-horizontal and vertical-moment envelopes initially coincide with the envelope for a single sand layer at low vertical loads, but show an abrupt reduction in the horizontal or moment capacity as the vertical load increases beyond a certain critical vertical load. The critical vertical load is found to vary as a function of the thickness and the lateral extent of the upper layer. Relationships are presented to enable the vertical-horizontal and vertical-moment envelopes to be estimated based on the problem geometry and material properties.The findings in this study provide insight into the response of subsea foundations placed on rock or gravel of limited extent overlying a clay seabed as well as the general response of shallow foundations on two-layer profiles.

AB - This study describes the numerical analyses performed to investigate the bearing capacity of strip footings placed on granular (frictional) material overlying soft clay subjected to combined vertical-horizontal and vertical-moment loading. A plane-strain finite element limit analysis is used to estimate the limiting load combinations for two layer soil geometries where the top layer is either fully extended in the horizontal direction or it is of limited horizontal extent, representative of rock or gravel berms commonly used in offshore practice.Bearing capacity envelopes for combined vertical, horizontal and/or moment loading are well-documented in the literature for cases of footings resting on single sand or clay soil. For two-layer sand-over-clay soil with a horizontally extensive top layer, the vertical-horizontal and vertical-moment envelopes initially coincide with the envelope for a single sand layer at low vertical loads, but show an abrupt reduction in the horizontal or moment capacity as the vertical load increases beyond a certain critical vertical load. The critical vertical load is found to vary as a function of the thickness and the lateral extent of the upper layer. Relationships are presented to enable the vertical-horizontal and vertical-moment envelopes to be estimated based on the problem geometry and material properties.The findings in this study provide insight into the response of subsea foundations placed on rock or gravel of limited extent overlying a clay seabed as well as the general response of shallow foundations on two-layer profiles.

U2 - 10.1016/j.sandf.2018.12.004

DO - 10.1016/j.sandf.2018.12.004

M3 - Article

SP - 433

EP - 442

JO - Soils and Foundations

JF - Soils and Foundations

SN - 0038-0806

ER -