TY - JOUR
T1 - Breast MRI
T2 - Early experience with a 3-D fat-suppressed gradient echo sequence in the evaluation of breast lesions
AU - Holden, A.
AU - Anderson, J. E.M.
AU - Ives, F. J.
AU - Taylor, D.
AU - Wylie, E. J.
AU - Adamson, R.
PY - 1996
Y1 - 1996
N2 - The early clinical experience with a 3-Dimensional Fourier Transform Gradient Echo sequence with fat suppression in the evaluation of breast masses is reported. Ten female patients with breast malignancies were pre-operatively evaluated with this sequence and the results compared with the pathological specimens. The scanning protocol included a non-contrast sequence followed by an immediate post-contrast sequence (completed 4.5 min after intravenous contrast injection) and a delayed sequence. Images were assessed for maximum lesion and parenchymal enhancement, lesion size and additional enhancing abnormalities. In six patients, malignant masses enhanced maximally on the immediate post-contrast sequence with parenchyma enhancing maximally on delayed images. In three cases, there was preferential enhancement of malignant lesions over normal parenchyma but to a similar degree on both post-contrast sequences. In one case, both the lesion and parenchyma enhanced maximally on the delayed sequence. Magnetic resonance assessed lesion size accurately and also detected satellite malignancies in one case. However, lesion grade, associated in situ carcinoma and lymphovascular invasion did not impact on lesion enhancement. In this small series, a contrast-enhanced, fat-suppressed 3-D Gradient Echo Sequence detected breast carcinoma with high sensitivity. The technique holds promise but further evaluation is required.
AB - The early clinical experience with a 3-Dimensional Fourier Transform Gradient Echo sequence with fat suppression in the evaluation of breast masses is reported. Ten female patients with breast malignancies were pre-operatively evaluated with this sequence and the results compared with the pathological specimens. The scanning protocol included a non-contrast sequence followed by an immediate post-contrast sequence (completed 4.5 min after intravenous contrast injection) and a delayed sequence. Images were assessed for maximum lesion and parenchymal enhancement, lesion size and additional enhancing abnormalities. In six patients, malignant masses enhanced maximally on the immediate post-contrast sequence with parenchyma enhancing maximally on delayed images. In three cases, there was preferential enhancement of malignant lesions over normal parenchyma but to a similar degree on both post-contrast sequences. In one case, both the lesion and parenchyma enhanced maximally on the delayed sequence. Magnetic resonance assessed lesion size accurately and also detected satellite malignancies in one case. However, lesion grade, associated in situ carcinoma and lymphovascular invasion did not impact on lesion enhancement. In this small series, a contrast-enhanced, fat-suppressed 3-D Gradient Echo Sequence detected breast carcinoma with high sensitivity. The technique holds promise but further evaluation is required.
KW - 3-dimensional Fourier transform gradient echo sequence
KW - fat suppressed
KW - malignant breast lesions
UR - https://www.scopus.com/pages/publications/0030497751
U2 - 10.1111/j.1440-1673.1996.tb00433.x
DO - 10.1111/j.1440-1673.1996.tb00433.x
M3 - Article
C2 - 8996898
AN - SCOPUS:0030497751
SN - 0004-8461
VL - 40
SP - 391
EP - 397
JO - Australasian Radiology
JF - Australasian Radiology
IS - 4
ER -