TY - JOUR
T1 - Aortic valve laceration following rotational atherectomy
T2 - a case report
AU - Othman, Farrah
AU - Yong, Gerald
AU - Whelan, Alan
AU - Ihdayhid, Abdul Rahman
N1 - Publisher Copyright:
© 2024 Oxford University Press. All rights reserved.
PY - 2024/6
Y1 - 2024/6
N2 - Background Iatrogenic aortic valve injury during cardiovascular catheterization interventions is extremely rare. Severe aortic regurgitation that ensues can be catastrophic and the management is typically with surgical valve replacement or repair. Percutaneous management of native pure aortic regurgitation is difficult due to anatomical challenges and the limitations of current transcatheter heart valve technology to anchor in the absence of leaflet or annular calcification. Case Summary An 82-year-old female underwent rotational atherectomy (RA) for a severely calcified stenosis of the left anterior descending artery. The patient was discharged well following placement of two drug eluting stents. She represented to hospital 7 days later with acute pulmonary oedema. Bedside transthoracic echocardiography demonstrated new, severe AR with preserved left ventricular size and function. Review of the prior percutaneous coronary intervention revealed significant trauma to the aortic valve during RA, with contrast seen refluxing into the LV during diastole, evolving throughout the procedure. Given the patient was not an operative candidate, an oversized transcatheter aortic valve was successfully implanted. In the post-operative setting, the patient suffered a stroke. Extensive hypoattenuated leaflet thickening (HALT) and thrombus was seen on dedicated 4D CT imaging. She made full neurological recovery and valve function returned to normal following a period of anticoagulation. Conclusion Although iatrogenic aortic valve laceration is rare, this case highlights several important learning points including the importance of good guide catheter support during RA; the feasibility of Transcatheter Aortic Valve Replacement for pure native AR; and the detection and management of HALT.
AB - Background Iatrogenic aortic valve injury during cardiovascular catheterization interventions is extremely rare. Severe aortic regurgitation that ensues can be catastrophic and the management is typically with surgical valve replacement or repair. Percutaneous management of native pure aortic regurgitation is difficult due to anatomical challenges and the limitations of current transcatheter heart valve technology to anchor in the absence of leaflet or annular calcification. Case Summary An 82-year-old female underwent rotational atherectomy (RA) for a severely calcified stenosis of the left anterior descending artery. The patient was discharged well following placement of two drug eluting stents. She represented to hospital 7 days later with acute pulmonary oedema. Bedside transthoracic echocardiography demonstrated new, severe AR with preserved left ventricular size and function. Review of the prior percutaneous coronary intervention revealed significant trauma to the aortic valve during RA, with contrast seen refluxing into the LV during diastole, evolving throughout the procedure. Given the patient was not an operative candidate, an oversized transcatheter aortic valve was successfully implanted. In the post-operative setting, the patient suffered a stroke. Extensive hypoattenuated leaflet thickening (HALT) and thrombus was seen on dedicated 4D CT imaging. She made full neurological recovery and valve function returned to normal following a period of anticoagulation. Conclusion Although iatrogenic aortic valve laceration is rare, this case highlights several important learning points including the importance of good guide catheter support during RA; the feasibility of Transcatheter Aortic Valve Replacement for pure native AR; and the detection and management of HALT.
KW - Case report
KW - Complication
KW - Iatrogenic aortic valve laceration
KW - Rotational atherectomy
KW - TAVR for native pure aortic regurgitation
UR - http://www.scopus.com/inward/record.url?scp=85195701681&partnerID=8YFLogxK
U2 - 10.1093/ehjcr/ytae226
DO - 10.1093/ehjcr/ytae226
M3 - Article
C2 - 38845809
AN - SCOPUS:85195701681
SN - 2514-2119
VL - 8
JO - European Heart Journal - Case Reports
JF - European Heart Journal - Case Reports
IS - 6
M1 - ytae226
ER -