@inproceedings{3b432bc62d844ec7ac8851135da9a9cd,
title = "An MLE method for finding LKB NTCP model parameters using Monte Carlo uncertainty estimates",
abstract = "The aims of this work were to establish a program to fit NTCP models to clinical data with multiple toxicity endpoints, to test the method using a realistic test dataset, to compare three methods for estimating confidence intervals for the fitted parameters and to characterise the speed and performance of the program. {\textcopyright} Published under licence by IOP Publishing Ltd.",
author = "M.G. Carolan and B.M. Oborn and K. Foo and A. Haworth and S.L. Gulliford and Martin Ebert",
year = "2014",
doi = "10.1088/1742-6596/489/1/012087",
language = "English",
isbn = "17426588",
volume = "489",
series = "Journal of Physics: Conference Series",
publisher = "IOP Publishing",
pages = "012087",
booktitle = "An MLE method for finding LKB NTCP model parameters using Monte Carlo uncertainty estimates",
address = "United Kingdom",
note = "17th International Conference on the Use of Computers in Radiation Therapy ; Conference date: 06-05-2013 Through 09-05-2013",
}