TY - JOUR
T1 - Accurate imputation-based screening of Gln368Ter myocilin variant in primary open-angle glaucoma
AU - Gharahkhani, P.
AU - Burdon, K.P.
AU - Hewitt, A.W.
AU - Law, M.H.
AU - Souzeau, E.
AU - Montgomery, G.W.
AU - Radford-Smith, G.
AU - Mackey, David
AU - Craig, J.E.
AU - Macgregor, S.
PY - 2015
Y1 - 2015
N2 - © 2015 The Association for Research in Vision and Ophthalmology, Inc. PURPOSE. Myocilin (MYOC) is a well-established primary open-angle glaucoma (POAG) risk gene, with rare variants known to have high penetrance. The most common clinically relevant risk variant, Gln368Ter, has an allele frequency of 0.1% to 0.3% in populations of European ancestry. Detection of rare MYOC variants has traditionally been conducted using Sanger sequencing. Here we report the use of genotyping arrays and imputation to assess whether rare variants including Gln368Ter can be reliably detected. METHODS. A total of 1155 cases with advanced POAG and 1992 unscreened controls genotyped on common variant arrays participated in this study. Accuracy of imputation of Gln368Ter variants was compared with direct sequencing. A genome-wide association study was performed using additive model adjusted for sex and the first six principal components. RESULTS. We found that although the arrays we used were designed to tag common variants, we could reliably impute the Gln368Ter variant (rs74315329). When tested in 1155 POAG cases and 1992 controls, rs74315329 was strongly associated with risk (odds ratio = 15.53, P = 1.07 × 10-9). All POAG samples underwent full sequencing of the MYOC gene, and we found a sensitivity of 100%, specificity of 99.91%, positive predictive value of 95.65%, and negative predictive value of 100% between imputation and sequencing. Gln368Ter was also accurately imputed in a further set of 1801 individuals without POAG. Among the total set of 3793 (1992 + 1801) individuals without POAG, six were predicted (probability > 95%) to carry the risk variant. CONCLUSIONS. We demonstrate that some clinically important rare variants can be reliably detected using arrays and imputation. These results have important implications for the detection of clinically relevant incidental findings in ongoing and future studies using arrays
AB - © 2015 The Association for Research in Vision and Ophthalmology, Inc. PURPOSE. Myocilin (MYOC) is a well-established primary open-angle glaucoma (POAG) risk gene, with rare variants known to have high penetrance. The most common clinically relevant risk variant, Gln368Ter, has an allele frequency of 0.1% to 0.3% in populations of European ancestry. Detection of rare MYOC variants has traditionally been conducted using Sanger sequencing. Here we report the use of genotyping arrays and imputation to assess whether rare variants including Gln368Ter can be reliably detected. METHODS. A total of 1155 cases with advanced POAG and 1992 unscreened controls genotyped on common variant arrays participated in this study. Accuracy of imputation of Gln368Ter variants was compared with direct sequencing. A genome-wide association study was performed using additive model adjusted for sex and the first six principal components. RESULTS. We found that although the arrays we used were designed to tag common variants, we could reliably impute the Gln368Ter variant (rs74315329). When tested in 1155 POAG cases and 1992 controls, rs74315329 was strongly associated with risk (odds ratio = 15.53, P = 1.07 × 10-9). All POAG samples underwent full sequencing of the MYOC gene, and we found a sensitivity of 100%, specificity of 99.91%, positive predictive value of 95.65%, and negative predictive value of 100% between imputation and sequencing. Gln368Ter was also accurately imputed in a further set of 1801 individuals without POAG. Among the total set of 3793 (1992 + 1801) individuals without POAG, six were predicted (probability > 95%) to carry the risk variant. CONCLUSIONS. We demonstrate that some clinically important rare variants can be reliably detected using arrays and imputation. These results have important implications for the detection of clinically relevant incidental findings in ongoing and future studies using arrays
U2 - 10.1167/iovs.15-17305
DO - 10.1167/iovs.15-17305
M3 - Article
SN - 0146-0404
VL - 56
SP - 5087
EP - 5093
JO - Investigative Ophthalmology and Visual Science
JF - Investigative Ophthalmology and Visual Science
IS - 9
ER -